Siemens MICROMASTER 4 PROFIBUS MODULE 6SE6400-1PB00-0AA0 – new PROFIBUS communication module: how to read the nameplate data and what to check when selecting it, version B08/1.03 from the label

Siemens MICROMASTER 4 PROFIBUS MODULE 6SE6400-1PB00-0AA0 – new PROFIBUS communication module: how to read the nameplate data and what to check when selecting it, version B08/1.03 from the label

Files to download

Share

New PROFIBUS communication module for MICROMASTER 4 inverters (6SE6400-1PB00-0AA0, version B08/1.03): how to read the label data, what to check when selecting and replacing it, and how to avoid fault F0070.

Siemens MICROMASTER 4 PROFIBUS MODULE 6SE6400-1PB00-0AA0 – new PROFIBUS communication module: how to read the nameplate data and what to check when selecting it, version B08/1.03 from the label

The PROFIBUS communication module is an optional card that is mounted on a MICROMASTER 4 inverter so that the drive can be controlled from a higher-level PLC over a PROFIBUS network. It is found in machines and lines where the drive is connected to a fieldbus, and when replacing a faulty module it is important not to change the rest of the inverter and network configuration. If you are looking for the 6SE6400-1PB00-0AA0 module, it is worth having at hand the nameplate and label data of the old module, as well as information about the power supply and the network address, because these determine whether the replacement goes ahead without interfering with the rest of the system.

The module at a glance

The 6SE6400-1PB00-0AA0 module connects a drive from the MICROMASTER 4 series to a higher-level automation system via PROFIBUS-DP, and a three-colour LED (green, orange, red) indicates the current status.

ParameterValue
Catalogue number6SE6400-1PB00-0AA0
Dimensions (height x width x depth)161 mm x 73 mm x 43.5 mm
Internal supply from the inverter6.5 V ± 5 %, max. 300 mA
External supply24 V ± 10 %, max. 350 mA
Operating temperature-10 °C to +50 °C
Transmission speed9.6 kbaud to 12 MBaud
PROFIBUS connector9-pin sub-D socket
Address on the DIP switches1 to 125, switches 1 to 7

The dimensions make it possible to judge whether the module will fit in the existing enclosure, and the operating temperature range has to be compared with the conditions in the cabinet in which the inverter operates.

What to watch out for when replacing

  • Internal supply from the inverter: the module can draw its power through the inverter system connector, in which case the voltage is 6.5 V ± 5 % and the current consumption is a maximum of 300 mA.
  • External supply: alternatively, the module can be powered from a local 24 V connection, with a voltage of 24 V ± 10 % and a consumption of max. 350 mA, with the inverter electronics also being powered in this case; before purchase, therefore, it is necessary to establish which way the old module is powered and to reproduce the same wiring.
  • Connector and segment length: the module is connected to the network through a 9-pin sub-D socket, and the maximum length of a single segment depends on the transmission speed: 1000 m for 9.6 to 187.5 kbaud, 400 m for 500 kbaud, 200 m for 1.5 MBaud and 100 m for 3 to 12 MBaud. Replacing the module does not change these limits, but if the speed in the network was raised at some point, it is worth checking whether the cable is within the limit.
  • PROFIBUS address: address 0 on the switches means that the address is set by parameter P0918, and values from 1 to 125 are valid addresses. Before removal, therefore, the position of the DIP switches of the old module and the value of P0918 should be written down, so that the new module reports in the network under the same address.
  • Restart after changing the switches: a change to the DIP switch settings takes effect only after a cold restart (power cycle), that is, after switching the power off and on again. Simply moving the switches while the device is running will therefore have no effect.
  • Visual inspection: the module housing, the contacts of the sub-D connector and the contact connecting the module to the inverter should be examined.
  • Reading the label: the catalogue number, serial number and version designation are copied from the label; on the label of this unit the entry B08/1.03 was read.
  • Origin of the module: it is worth keeping the purchase document and noting where the module comes from, because this makes it easier to establish the history of the device later in the machine documentation.
  • Photos before ordering: photos of the nameplate and connectors, taken before the order is placed, make it possible to compare the appearance and markings of the new module with the old one.

Before making an enquiry or a purchase, prepare the full type designation from the nameplate, the serial number, the version from the label, photos of the label and connectors, data on the inverter in which the module operates, a short description of the application, and information on whether the module is powered from the inverter or from an external 24 V source. Such data make it possible to confirm the catalogue number unambiguously, without guessing from appearance alone.

General replacement steps

The replacement is carried out by qualified personnel, and the order of actions has one purpose: the new module is to take over exactly the settings of the old one.

  1. Writing down the inverter settings and the PROFIBUS address before removal.
  2. Switching off the inverter power supply and any external 24 V supply.
  3. Removing the old module and checking the contacts on the inverter side.
  4. Mounting the new module so that it is firmly latched on the inverter.
  5. Setting the DIP switches according to the recorded address.
  6. Connecting the PROFIBUS fieldbus through the sub-D connector and, if applicable, the 24 V supply.
  7. Switching on the power, which is a cold restart and activates the switch settings.
  8. Checking the module status LED and the communication with the controller.

Good practice is to check control via PROFIBUS before starting the motor; for this, the motor cable can be disconnected from terminals U, V and W and the output frequency observed on the BOP or AOP panel. If communication does not work after start-up, the first things to check are the latching of the module on the inverter, the condition of the connectors and the correctness of the bus termination at both ends.

Questions and answers

How is the address set with the DIP switches?

Switches 1 to 7 have weights of 1, 2, 4, 8, 16, 32 and 64, and the address is the sum of the weights of the switches set to "on". Manufacturer's example: address 3 is switches 1 and 2 on, with the others off; address 88 is switches 4, 5 and 7 on. Addresses 126 and 127 are invalid, and a change takes effect only after the power is switched off and on again.

What do the orange and red LEDs of the module mean?

The orange LED signals a communication failure with the PROFIBUS master, and the red one – a communication failure between the inverter and the module. In both cases the inverter reports the same fault, F0070. With the orange LED the causes have to be sought in the network: interference, a cable that is too long, incorrect bus termination or a badly seated connector, and with the red one the first thing to check is whether the module is firmly seated on the inverter and whether the contacts are damaged.

Does the module have to have a 24 V supply in order to work in the network?

No, the module can be powered from the inverter. A permanent 24 V supply is, however, useful in nodes where the bus ends, because the termination requires 5 V to be available, and an inverter that is switched off will not provide it.

Enetiv works in industrial automation from two sides: we supply parts and we repair them. We have new, used and refurbished parts from brands including Allen-Bradley (Rockwell Automation), Siemens, Schneider Electric, Bosch Rexroth and ABB, we diagnose and repair inverters, servo drives, I/O modules and controllers, we service motors and servomotors, with our own warranty on repairs. We also specialize in end-of-life (EOL) parts and service, including older-generation and unusual components. Please contact us at https://enetiv.com/zapytanie.